IMPORTANT - PLEASE READ AND FOLLOW
Before beginning, please read these instructions completely and carefully.
Do not remove permanently affixed labels, warnings, or plates from the product. This
may void the warranty.
Please observe all local and national codes and ordinances.
Please ensure that this product is properly grounded.
The installer should leave these instructions with the consumer who should retain
for local inspector’s use and for future reference.
The electrical plug should always be accessible.
Installation must conform with local codes or in the absence of codes, the National Fuel
Gas Code ANSIZ223.1 - Iatest edition. Electrical installation must be in accordance
with the National Electrical Code, ANSI/NFPA70 - latest edition and/or local codes. IN
CANADA: Installation must be in accordance with the current CAN/CGA-B149.1 National
Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes.
Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical
Codes Part 1 and/or local codes.
INSTALLATION IN MANUFACTURED (MOBILE) HOME: The installation must conform with the
Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the
Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)] or, when
such standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS
A225.1, or with local codes where applicable.
INSTALLATION IN RECREATIONAL PARK TRAILERS: The installation must conform with state or
other codes or, in the absence of such codes, with the Standard for Recreational Park Trailers, ANSI
A119.5.
Installation of any gas-fired equipment should be made by a Iicensed plumber. A manual shut-off
valve must be installed in an accessible location in the gas line external to the appliance for the
purpose of turning on or shutting off gas to the appliance (In Massachusetts such shutoff devices
should be approved by the Board of State Examiners of Plumbers & Gas Fitters).
If an external electrical source is utilized, the appliance, when installed, must be electrically
grounded in accordance with local codes or, in the absence of local codes, with the national
Electrical Code, ANSI/NFPA 70.
This range is supplied with a protective film on steel and aluminium parts.
This film must be removed before installing/using the appliance.
FOR INSTALLER ONLY
THIS RANGE IS FOR RESIDENTIAL USE ONLY
• INSTALLATIONINSTRUCTIONS
IMPORTANT - PLEASE READ AND FOLLOW
SINGLE CAVITY GAS RANGE
for residential use only
Models: VEFSGG 365 N..
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - SINGLE CAVITY GAS RANGE

IMPORTANT - PLEASE READ AND FOLLOW✓ Before beginning, please read these instructions completely and carefully.✓ Do not remove permanently affixed la

Page 2 - WITH RANGE

10Fig. 1.4FITTING THE ADJUSTABLE FEETThe adjustable feet must be fitted to the base of the cooker before use.Rest the rear of the cooker on a piece o

Page 3 - CONVERSION LABEL

11ABABAABBFig. 1.8Fig. 1.9ASSEMBLING THE BACKGUARD OR THE ISLAND TRIMIt is mandatory to install the backguard or the island trim• Assemble the backg

Page 4 - INSTALLATION INSTRUCTIONS

12ANTI-TIP STABILITY DEVICE INSTALLATION INSTRUCTIONS1. The anti-tip bracket has to be attached as shown on figure below, it has to be fixed on the re

Page 5 - WARNING!!

13Gas supply lineShutoff valve“open” positionTo rangeFig. 2.1All gas connections must be made according to national and local codes. This gas supply (

Page 6 - PROXIMITY TO SIDE CABINETS

14PRESSURE REGULATOR INSTALLATIONLOCKArrowSTEP 2Assemble the 1/2” NPT connector + pressure regulator group to the extension pipe interposing the gask

Page 7 - GAS AND ELECTRIC CONNECTION

15AASTEP 3Insert the extension pipe + pressure regulator group in the “A” bracket.STEP 4Assemble the extension pipe + pressure regulator group to the

Page 8 - OVEN VENT

16BBSTEP 5Fix the “B” bracket on the back of the range by the 2 (two) screws supplied with the kit for gas connection.The regulator cover must be ordi

Page 9 - 12"

17ConnectorPressureregulator1/2” G cylindrical(ISO 228-1) female1/2” NPT(conical)male1/2” NPTfemale1/2” NPTfemale1/2” G cylindrical(ISO 228-1) maleExt

Page 10 - 0"

18Fig. 2.4TEST POINT ADAPTERThe Test Point adapter is available from the After-Sales Service.c) Any conversion required must be performed by your dea

Page 11 - OR THE ISLAND TRIM

1912NATURAL GASREGULATIONLP/PROPANEREGULATIONAcomponentFig. 2.5REGULATORCOVERPressure regulatorCONVERSION TO LP/PROPANE GASEvery range is provided wit

Page 12 - 17"

2✓ Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.✓ WHAT TO DO IF YOU SMELL GAS:• D

Page 13 - Explosion Hazard

20OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS✓ Remove the gratings and the burner covers;✓ Using a wrench substitute the nozzle inject

Page 14

21SETTING THE BURNER MINIMUMWhen switching from one type of gas to another, the minimum flow rate must also be correct: the flame should not go out e

Page 15

22OPERATIONS TO BE EXECUTED FOR THE REPLACEMENT OF THE INJECTORS OF THE OVEN AND BROIL BURNERSa) Oven Burner – Lift and remove the lower panel inside

Page 16 - Fig. 2.2e

23ADJUSTMENT OF THE OVEN BURNER MINIMUMThis needs to be done only for the oven burner (the broil is a fixed capacity) by acting on the thermostat in t

Page 17 - GAS CONNECTION SPECIFICATION

24If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.Check

Page 18 - 5. Leak Testing:

25WIRING DIAGRAM

Page 21 - SETTING THE BURNER MINIMUM

Cod. 1104634 - ß1The manufacturer cannot be held re spon sible for possible inaccuracies due to printing or transcription errors in the present bookle

Page 22 - OVEN AND BROIL BURNERS

3DATA PLATECONVERSION LABELThis appliance is designed and manufactured solely for the cooking of domestic (household) food and in not suitable for any

Page 23

4WARNING!THIS APPLIANCE HAS TO BE INSTALLED BY A QUALIFIED INSTALLER.Improper installation, adjustment, alteration, services, or maintenance can cause

Page 24 - VERY IMPORTANT

5GENERAL INFORMATION1. Installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-Lat

Page 25 - WIRING DIAGRAM

6installationPROXIMITY TO SIDE CABINETS1. This range may be installed directly adjacent to existing 36” (914 mm) high base cabinets. Range dimension

Page 26

7CDBAGAS AND ELECTRIC CONNECTIONDotted line showing the positionof the range when installed* : Depending on feet regulationArea for GAS connectionArea

Page 27

8(457 mm)18" min.30" min.(762 mm)(914 mm)36"0"(0 mm)0"(0 mm)20" min. (500 mm)11" 13/16 min. (300 mm)13" max. (

Page 28 - Cod. 1104634 - ß1

9Fig. 1.3cFig. 1.3dPROXIMITY TO SIDE CABINETSRANGE WITH ISLAND TRIM(457 mm)18" min.30" min.(762 mm)(914 mm)36"0"0"(0 mm)(0 m